The seventh title of ISO 9001 Quality Management System standard clauses is determined as service realization. The sixth item of this heading is the control of monitoring and measuring devices.

In order to ensure that their monitoring and measurement results are reliable, companies have to perform the calibration and verification of the tools they use in this business. In addition, during the transportation and storage of these devices when not in use, necessary precautions must be taken to prevent situations that would invalidate the monitoring and measurement results.

Companies are committed to monitoring and measuring In order to carry out their operations and to prove the conformity of the products to the conditions determined, they must determine which monitoring and measurement intervals they will use.

In addition, monitoring and measuring instruments must be calibrated or verified at regular intervals or before use, in accordance with national and international measuring standards, in order to obtain valid results in each case. Companies have to prevent and avoid these devices from being out of alignment in order to invalidate the measurement results. In particular, these devices must be protected against damage and deterioration during transport, maintenance or storage. It should also be kept away from dust, moisture and extreme low or high temperature as much as possible.

All measuring devices within the company affecting product and service quality, ISO 9001. The measuring devices to be prepared by the quality management representative must be registered in the calibration follow-up list. This list also shows devices that do not affect product quality and are excluded from calibration.

Calibration intervals, type of monitoring and measuring instruments, operating conditions and location. If the expected accuracy is not achieved, the calibration intervals can be shortened.

If the measurement results of the measuring instruments are suspected, or if the measuring instrument has not been stored under the appropriate conditions, although within the calibrated range, the instrument must be recalibrated. These measuring devices must never be adjusted by company personnel. Verification should be requested by informing the company about the situation.

There are other points of doubt about the control of monitoring and measuring devices. our company TÜRCERT Technical Control and Certification The company has a strong staff and technical infrastructure to support this issue as in all quality systems.